Installation method of DVR-C voltage sag compensator
Characteristics of DVR-C voltage sag compensator: fast high wide long stable
1. The response speed of voltage compensation: A few milliseconds of voltage disturbance can affect sensitive equipment, so the rapid response of compensation voltage is an important parameter for measuring equipment performance,
The product achieves an extremely fast response time of less than 2 milliseconds through the independently invented vacuum carrier technology, and even precision machining equipment cannot feel the occurrence of voltage fluctuations.
2. High precision of voltage compensation: The DVR-C control system based on CPU dual core adjustment chip can achieve precise control of compensation voltage with an accuracy of up to 99%.
3. The allowable range of voltage compensation is wide: different solutions can solve the long-term voltage disturbance DVR-C on the customer's site, and the allowable range of voltage compensation is 0-130%.
4. Long voltage compensation time: Depending on the needs of different application environments of customers, the energy storage compensation device DVR-C can provide compensation time of 500ms-12 seconds or longer (customizable). The DVR-C, a system continuous energy harvesting product, can provide 30 second voltage drop compensation and is suitable for narrow range± Provide long-term protection against voltage disturbances within 20%.
5. Voltage compensation protection: complete self diagnostic function: equipment quick switch, inverter and other key components are equipped with self diagnostic function to ensure early warning of device failures and long-term stable operation of the equipment without potential threats to the main circuit operation due to equipment reasons.
Product selection:
Product specifications:
Working conditions |
High relative humidity: 90% RH |
Basic electrical parameters |
Rated frequency: 50Hz |
Connection method |
Single phase or three-phase four wire system, cable connection |
Insulation level |
H-level (F-level under normal operating conditions) |
Protection level |
IP30 |
Execution standards |
SD292-88、GB/T14549-1993、GB10941-1996、GB19212.1-2003、GB6450-1986、 GB/T501-1991、GB50052-2009。 |
Installation method of DVR-C voltage sag compensator
Characteristics of DVR-C voltage sag compensator: fast high wide long stable
1. The response speed of voltage compensation: A few milliseconds of voltage disturbance can affect sensitive equipment, so the rapid response of compensation voltage is an important parameter for measuring equipment performance,
The product achieves an extremely fast response time of less than 2 milliseconds through the independently invented vacuum carrier technology, and even precision machining equipment cannot feel the occurrence of voltage fluctuations.
2. High precision of voltage compensation: The DVR-C control system based on CPU dual core adjustment chip can achieve precise control of compensation voltage with an accuracy of up to 99%.
3. The allowable range of voltage compensation is wide: different solutions can solve the long-term voltage disturbance DVR-C on the customer's site, and the allowable range of voltage compensation is 0-130%.
4. Long voltage compensation time: Depending on the needs of different application environments of customers, the energy storage compensation device DVR-C can provide compensation time of 500ms-12 seconds or longer (customizable). The DVR-C, a system continuous energy harvesting product, can provide 30 second voltage drop compensation and is suitable for narrow range± Provide long-term protection against voltage disturbances within 20%.
5. Voltage compensation protection: complete self diagnostic function: equipment quick switch, inverter and other key components are equipped with self diagnostic function to ensure early warning of device failures and long-term stable operation of the equipment without potential threats to the main circuit operation due to equipment reasons.
Product selection:
Product specifications:
Working conditions |
High relative humidity: 90% RH |
Basic electrical parameters |
Rated frequency: 50Hz |
Connection method |
Single phase or three-phase four wire system, cable connection |
Insulation level |
H-level (F-level under normal operating conditions) |
Protection level |
IP30 |
Execution standards |
SD292-88、GB/T14549-1993、GB10941-1996、GB19212.1-2003、GB6450-1986、 GB/T501-1991、GB50052-2009。 |